The scaling calculator in IPEmotion can support the sensor database, and in the sensor database, IPEmotion has integrated many commonly used sensors. Select the sensor from the sensor database, the physical range, output range, power supply and other parameters of the sensor have been set, which provides convenience for practical applications. In the actual use of IPEmoiton, a specific sensor database can be set in accordance with application requirements, and a new sensor can be added through the sensor database editor (IPE-SDEditor) and the scaling calculator. The detailed operation steps will be introduced below.

1. IPE-SDEditor add sensor

The storage location of IPE-SDEditor is: C: \ Program Files (x86) \ IPETRONIK \ IPEmotion 2017 R1.1 \ Tools. If you want to add the sensor to an existing database, you need to configure the database. The database is installed in the following directory: C: \ ProgramData \ IPETRONIK \ IPEmotion 2017 R1.1 \ Database.

The configuration steps are as follows:

1. Open IPE-SDEditor and click the File button to open the database file.

Sensor database for IPEmotion applications

Sensor database for IPEmotion applications

2. Click the Add Sensor button to add a sensor to the database.

Sensor database for IPEmotion applications

3. On the general interface, set the sensor name, type, physical range, output range, power supply and other parameters. The content with "*" must be set before the sensor can be saved to the database.

Sensor database for IPEmotion applications

4. Configure other sensor information on the UserProperties interface, such as operating temperature range.

Sensor database for IPEmotion applications

5. Configure the serial number, calibration date, and calibration time limit information on the SpecificSensors interface.

Sensor database for IPEmotion applications

6. Save the settings and restart IPEmotion, the new sensor will be included in the database.

Sensor database for IPEmotion applications

Two, zoom calculator to add sensors

1. Open the zoom calculator, configure the added sensor, and then click to add a new custom sensor setting.

Sensor database for IPEmotion applications

2. Set the sensor type, manufacturer, name, and serial number, and click OK.

Sensor database for IPEmotion applications

3. The new sensor is saved in the database.

Sensor database for IPEmotion applications

The storage path of the sensor database file added by the scaling calculator: C: \ Users \ Public \ Documents \ IPETRONIK \ IPEmotion \ Database \ IPESensorDatabase.xmu.

Pocket Spring Pillow

Pocket Spring Pillow,Pillow,Pocket Spring Pillow,Hotel Pillow

HESHAN HAIMA FURNITURE CO., LTD , https://www.springmattress.com