[ Chinese wardrobe net ] The outer dimensions of the cloakroom are the size of the cloakroom. This is mainly determined by the size of the home space. The average family room small room is 8-12 square meters, the large room is 14-18 square meters, and the floor height is 2.5-2.8 meters. Then the size of the cloakroom is about 2000mm, 2200mm, 2400mm, 2600mm, 3200mm, 3800mm, 4200mm and other width specifications, 300mm, 450mm, 500mm, 550mm, 600mm and other depth specifications. Therefore, the cloakroom is divided into different types of cloakrooms depending on the size of the space. For example, the open cloakroom is for a relatively large space, using an empty wall for storage, not completely closed, such a cloakroom is relatively large in size; the independent cloakroom, hence the name "stand-alone", requires a separate space to design, then need The cloakroom has more space; these two cloakrooms are designed for large home spaces. For many small home spaces, you can choose the built-in cloakroom. This cloakroom saves space. The size of the cloakroom is more than 4 square meters. This space shape is made. The size of the cloakroom is determined by the owner's home space, but the size of the cloakroom should be at least 4 square meters. How to determine the size of the cloakroom design The outer dimensions of the cloakroom are related to the size of the home space, so the internal dimensions of the cloakroom are related to the life of the calendar. The interior dimensions of the cloakroom are made up of different patterns to meet different functional requirements. Here is a detailed explanation for everyone. The size of the cloakroom design is determined by the height of the clothes rails of 1700mm, 1300mm, and 900mm, which are used to hang long coats, short tops, and trousers. The distance between the clothes rail and the upper panel is between 40-60mm. How to determine the size of the cloakroom is 400-500mm. How to determine the size of the cloakroom is about 1000-1200mm. The size of the cloakroom design is defined by the drawer width of 400-800mm. How to define the size of the cloakroom? The size of the single frame is 80-100mm. How to determine the size of the cloakroom, the height of the stacking area is 350mm-500mm. How to determine the size of the cloakroom between the height of the long-sleeved area of ​​1400-1700mm. The size of the cloakroom design is set at a height of 80-100mm for the baseboard and 80-100mm for the height of the wardrobe trousers. The distance between the drawer and the ground is preferably less than 1250mm, especially for the elderly, it should be considered about 1000mm, which is convenient to use. How to determine the size of the cloakroom Shoe cabinet size is 200mm wide, 150mm high and 300mm deep, the width of the low boots is 280mm, the height is 300mm, and the height of the high boots is 500mm. After reading Xiaobian to tell you how to determine the size of the cloakroom design, do you know how to arrange the size of the cloakroom? If you are not sure, it is helpful to refer to the above data. Ground screw anchor are generally cut, deformed, welded, pickled, hot-dipped, and other processes to produce qualified piles. Among them, pickling and hot-dip galvanizing are important treatment processes that directly affect the service life of the screw piles. Ground Screw Anchor,Ground Screw Post Anchor,No Dig Ground Anchor,Ground Screw Pole Anchor Shijiazhuang Qiancen Industry Co.,ltd , https://www.yuyilang.com
The processing level of the pile directly determines the service life of the metal pile, such as the quality of the selected welded pipe, the quality level of welding, whether there are blisters, virtual welding, and the width of the welding. These all affect the future service life of the pile and the quality of subsequent processing. Pickling is an important foundation process, and the quality of hot-dip coating, such as the time of hot-dip coating, and the appearance of surface treatment, all affect the quality of pile treatment. Under normal circumstances, spiral piles can be used for 40-80 years. The environment and application method of the application process also affect the service life of the pile. For example, the acidity of the soil, whether the operation process is proper, or improper use will cause damage to the surface of the metal pile and damage the metal protective layer. Corrosion of metal piles is accelerated, reducing service life.
How to use spiral piles in messy terrain?
For the terrain, there should be many different terrains. How to deal with the messy terrain?
If it is a severe situation that the drilling tool cannot be lifted and released, and the impactor does not sound, now as long as the rated torque is added or auxiliary tools are used to assist in the improvement, the drilling tool is reversed, and then it is required to increase the drilling tool while air is being supplied. , Until the problem processing stops. During heavy drilling, first apply a little pressure, and then gradually increase the propulsion force until the normal working pressure is reached.