The company specializes in supplying Elisa kits, quality assurance, price concessions, and can provide free testing services, please call to consult!

This manual is for reference only, subject to the company's current provision, please call to obtain it. This kit can only be used for scientific research, not for medical diagnosis.

Human cathepsin antibody (Cath Ab) quantitative detection kit (ELISA)

user's Guide

[Human cathepsin antibody (Cath Ab) ELISA kit name]

Human cathepsin antibody (Cath Ab) quantitative detection kit (ELISA)

[Human cathepsin antibody (Cath Ab) ELISA kit kit uses]

Quantitative detection of serum, plasma and related fluids.

【Principle of detection of human cathepsin antibody (Cath Ab) ELISA kit】

This kit uses double-antibody two-step sandwich enzyme-linked immunosorbent assay (ELISA). Add the standard and the test sample to the pre-coated human cathepsin antibody (Cath Ab) monoclonal antibody transparent enzyme label coating plate. After incubation for a sufficient time, wash to remove unbound components, and then add the enzyme label working solution After sufficient incubation time, wash to remove unbound components. Substrates A and B are added in sequence, and the substrate (TMB) is converted into a blue product catalyzed by horseradish peroxidase (HRP) and turns yellow under the action of acid. The shade of the color and the human cathepsin antibody in the sample The concentration of (Cath Ab) is positively correlated. The OD value is measured at a wavelength of 450 nm. Based on the OD value of the standard and the sample, the content of human cathepsin antibody (Cath Ab) in the sample is calculated.

[Reagents and equipment not required by human cathepsin antibody (Cath Ab) ELISA kit]

1. 37 ℃ thermostat

2. Standard specification microplate reader

3. Precision pipettes and disposable tips

4. Distilled water

5. Disposable test tubes

6. Absorbent paper

[Composition of human cathepsin antibody (Cath Ab) ELISA kit]

1

Enzyme coated plate

12 holes × 8

7

Developer A liquid

6mL

2

Standard

0.3mL × 6 tubes

8

Developer B liquid

6mL

3

20 times concentrated washing liquid

25mL

9

Stop solution

6mL

4

Sample diluent

6mL

10

Instructions

1 serving

5

Special diluent

6mL

11

Sealing film

2 sheets

6

Enzyme reagent

6mL

12

sealed bag

1

[Operation steps of human cathepsin antibody (Cath Ab) ELISA kit]

1. Preparation: Remove the reagent kit from the refrigerator and re-equilibrate at room temperature for 30 minutes.

2. Mixing solution: dilute the 20-fold concentrated washing solution with distilled water to the original one.

3. Add standard products and samples to be tested: take a sufficient number of enzyme-coated plates and fix them to the frame. Set up standard wells, sample wells to be tested and blank control wells, record the positions of each well in the standard wells. Add 50μL of standard product; first add 10μL of sample to be tested, and then add 40μL of sample diluent (that is, the sample is diluted 5 times); blank control well is not added.

4. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

5. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each hole with the washing solution, let stand for 1min, shake off the washing solution, pat dry on the absorbent paper, repeat the washing 4 times (you can also use the washing machine to press Instructions for washing the board).

6. Add enzyme-labeled working solution: add 50μL of enzyme-labeled working solution to each well, without adding blank control wells.

7. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.

8. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each hole with washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the plate washing 4 times (you can also use the washing machine to press Instructions for washing the board).

9. Color development: add 50μL of developer A solution to each well, and then add 50μL of developer B solution, mix for 30s with a plate mixer (or gently shake for 30s by hand), and avoid color development at 37 ℃ for 15min .

10. Termination: Remove the enzyme labeling plate and add 50μL of stop solution to each well to stop the reaction (the color changes from blue to yellow)

11. Determination: Zero the blank holes, and within 15 minutes after termination, measure the absorbance (OD value) of each well with a wavelength of 450 nm.

12. Calculation: According to the concentration of the standard product and the corresponding OD value, calculate the linear regression equation of the standard curve, and then calculate the corresponding sample concentration on the regression equation according to the OD value of the sample. You can also use various application software to Calculation. The final concentration is the actual measured concentration times the dilution factor.

【Precautions for human cathepsin antibody (Cath Ab) ELISA kit】

1. The experiment is carried out in strict accordance with the instructions, and the result of the experiment must be determined by the reading of the microplate reader.

2. If the enzyme-labeled coated board is not used up after opening, it should be put into a sealed bag and added with desiccant immediately.

3. It is recommended that all standards, samples and blank controls be tested in duplicate, and the average value is taken to reduce the experimental error.

4. Keep in mind that the sample has been diluted 5 times. The calculation result is multiplied by 5 to obtain the actual concentration of the sample.

5. The quantitative range of this kit is 6.25-200ng / L. If it exceeds this range, it is calculated from the extension of the standard curve. It is not used for accurate quantitative results. ), Multiplied by the total dilution factor is the final concentration of the sample.

6. If the color is too light, the substrate incubation time can be extended properly.

7. In order to avoid cross-contamination, the tips, samples and blank controls should be replaced with a new one for each addition; the common components such as enzyme working solution, sample diluent and substrate should be cantilevered, and they should not touch the microwells. ; Do not reuse the sealing film.

8. The kits are used within the warranty period, and different batches of reagents should not be mixed.

9. Substrate B is sensitive to light and avoid prolonged exposure to light.

[Sample requirements for human cathepsin antibody (Cath Ab) ELISA kit]

1. The sample cannot contain sodium azide (NaN3) because sodium azide (NaN3) is an inhibitor of horseradish peroxidase (HRP).

2. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.

3. The sample should be fully centrifuged, without hemolysis and particles.

[Summary of operating procedures of human cathepsin antibody (Cath Ab) ELISA kit]

Prepare reagents, samples and standards

Add prepared samples and standards, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add the enzyme reagent, and react at 37 ℃ for 30 minutes

Wash the plate 4 times, add color developing solutions A and B, and develop at 37 ℃ for 15 minutes

Add stop solution

Read OD value within 15 minutes

Calculation

【Scope of detection of human cathepsin antibody (Cath Ab) ELISA kit】

Please inquire

【Specification of human cathepsin antibody (Cath Ab) ELISA kit】

96 servings / box 48 servings / box

【Storage of human cathepsin antibody (Cath Ab) ELISA kit】

Store at 2-8 ℃, protected from light and moisture.

[Human cathepsin antibody (Cath Ab) ELISA kit validity]

6 months

Even the biggest, heaviest blooms like peonies can hold their heads high with the help of these flower supports. Set them out in spring and stems will grow right up through the supports, keeping plants standing straight and tall and preventing unsightly flopping. The concentric rings forming the top of the support hold stems in more natural form than grid-shaped supports. The 12" support is ideal for short to medium-height flowers, including compact varieties of coreopsis, zinnia, campanula and veronica. The 18" support is perfect for shrubby flowers like taller zinnias, salvia, young peonies, Shasta daisies and poppies. The 24" support holds larger plants, like mature peonies, campanula and rudbeckia.

Give your tomatoes and other sprawling Vine and top heavy plants adequate room to flourish while keeping them nicely contained.

Vertical support for Vegetable plants

Plant Support

Plant Supports,Landscape Stakes Metal,Tomato Wire Cage,Metal Plant Supports

Tianjin Panyam Garden & Horticultural Products Co., Ltd. , https://www.panyahomegarden.com